¼ºÀα³Á¤¿¬±¸È¸ °Ô½ÃÆÇ
¼ºÀα³Á¤¿¬±¸È¸ °Ô½ÃÆÇ

2018/02/21 (00:33) from 112.169.179.145' of 112.169.179.145' Article Number : 3124
Delete Modify °ü¸®ÀÚ Access : 12374 , Lines : 115
ȲÇö½Ä ±³¼ö ÃÊû ÀÓ»ó±³Á¤ Ưº°°­¿¬È¸¸¦ ¾È³» µå¸³´Ï´Ù
    A New BlueOcean in Orthodontic Practice, Middle-Aged Adult Orthodontics

ȲÇö½Ä ±³¼ö ÃÊû ÀÓ»ó±³Á¤ Ưº°°­¿¬È¸

              ÁßÀå³â ¼ºÀα³Á¤

Bioefficient Treatment using Low-profile Appliance and Light Force Technology



»çȸ°æÁ¦Àû ¿©°ÇÀÇ Çâ»ó°ú ÇÔ²² ±×¸®°í Àα¸ÀÇ ³ë·ÉÈ­¿Í ´õºÒ¾î ¼ºÀΠƯÈ÷ ÁßÀå³â ¼ºÀα³Á¤ ȯÀÚ°¡ ±ÞÁõÇÏ°í ÀÖ½À´Ï´Ù. º¸Ã¶À̳ª Ä¡ÁÖÄ¡·áÀÇ ¿¹Èĸ¦ ÁÁ°Ô Çϱâ À§ÇÏ¿© ±³Á¤Ä¡·á¸¦ µ¿¹ÝÇÏ´Â º¸Á¶Àû ±³Á¤Ä¡·áÀÇ °æ¿ìµµ ÀÖÁö¸¸, ÀþÀº ¼ºÀο¡¼­Ã³·³ ´Ü¼øÈ÷ ½É¹Ì¸¦ À§ÇØ, ±×¸®°í "º¸´Ù Àþ¾îÁö°íÀÚ ÇÏ´Â" ¶Ç´Â "Àþ°Ô º¸ÀÌ°íÀÚ ÇÏ´Â" ¿ä±¸¿¡ ÀÇÇÑ ±³Á¤Ä¡·á, ¼ÒÀ§ Anti-aging °³³äÀÇ ±³Á¤ÀÌ Å©°Ô Áõ°¡ÇÏ¿´½À´Ï´Ù. ³ª¾Æ°¡ ÀÚ¿¬Ä¡¾Æ ¾Æ³¢±â ¿îµ¿ÀÇ È®»ê°ú ÇÔ²² °Ç°­ÇÏ°Ô Ä¡¾Æ¸¦ º¸Á¸ÇÏ°íÀÚ ¡°Ä¡ÁÖȯ°æ °³¼±¡±À» À§ÇØ ±³Á¤Ä¡¸¦ ÇÏ´Â °æ¿ì ¶ÇÇÑ ±ÞÁõÇÏ¿©, ÁßÀå³â ¼ºÀα³Á¤ÀÇ ¼ö¿ä´Â ±×¾ß¸»·Î Æø¹ßÀûÀ̶ó ÇÒ ¼ö ÀÖ½À´Ï´Ù.

±×µ¿¾È ±³Á¤Ä¡·á°¡ ÇÊ¿äÇÑ ÁßÀå³âÀÌ ±³Á¤Ä¡·á ½Ã ºÒÆí°¨°ú µ¿ÅëÀ¸·Î ÀÎÇØ Ä¡·á¸¦ ÁÖÀúÇϰųª Æ÷±âÇÏ´Â ÀÏÀÌ Á¾Á¾ ÀÖ¾î¿Â °ÍÀÌ »ç½ÇÀÔ´Ï´Ù. ±×·¯³ª Ãֽű³Á¤ÇÐÀÇ ¹ß´Þ°ú ÇÔ²² Low profile ÀåÄ¡¸¦ »ç¿ëÇÏ¿© Light force¸¦ ÀûÀýÇÏ°Ô ¾µ ¼ö ÀÖ´Â ±³Á¤ÀåÄ¡ µîÀÌ °³¹ßµÈ ¹Ù ÀÌÁ¦´Â ½Ç·Î ¡°Æí¾ÈÇÑ¡± Ä¡·á°¡ °¡´ÉÇÏ°Ô µÇ¾ú½À´Ï´Ù. ¾Æ¿ï·¯ º» °­¿¬È¸¿¡¼­´Â ÃÖ±Ù °³¹ßµÈ 022Æ©ºê¸¦ ÀÌ¿ëÇÑ Áõ·ÊµéÀÌ ¹ßÇ¥µÉ ¿¹Á¤À̾î, light force¸¦ ÀÌ¿ëÇÑ ¼ÒÀ§ ¡°¹«Åë±³Á¤¡±ÀÌ complicated case±îÁö °¡´ÉÇÔÀ» º¸¿©ÁÙ °ÍÀ¸·Î Å©°Ô ±â´ëÇÏ°í ÀÖ½À´Ï´Ù. º» Ưº°°­¿¬È¸¸¦ ÅëÇÏ¿© ±³Á¤Ä¡·áÀÇ ¿Ü¿¬ÀÌ Å©°Ô ³Ð¾îÁú °ÍÀ¸·Î ±â´ëÇÏ¸ç °ü½ÉÀÖ´Â ºÐµéÀÇ ¸¹Àº ¼º¿ø ºÎŹµå¸³´Ï´Ù.


        ÀϽÃ: 2018³â 3¿ù4ÀÏ(ÀÏ) 2:00-6:30 PM
        Àå¼Ò: ¼­¿ï´ëÇб³Ä¡°úº´¿ø 8Ãþ ´ë°­´ç
        ¿¬ÀÚ: Ȳ Çö ½Ä ±³¼ö


       
  ¿¬ÀÚ:  È²Çö½Ä ±³¼ö

1983 ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Á¹¾÷
1993 Ææ½Çº£´Ï¾Æ Ä¡´ë (Ä¡ÁÖ±³Á¤ ¿¬¼ö)
1995 Å׳׽à ġ´ë (¼ºÀα³Á¤ ¿¬¼ö)
       2003 ÆÛ½ÃÇÈ Ä¡´ë (Åõ¸í±³Á¤ ¿¬¼ö)
Àü³²´ëÇб³ Ä¡°ú´ëÇÐ ¸í¿¹±³¼ö
       ¹Ì±¹ »÷ÇÁ¶õ½Ã½ºÄÚ UOPÄ¡´ë °âÀÓ±³¼ö
Çѱ¹¼ºÀα³Á¤¿¬±¸È¸ ¿î¿µÀ§¿ø




Á¦1¼º  Æí¾ÈÇÑ ¼ºÀα³Á¤, MTA·Î °¡´É !

³ªÀÌ°¡ ¸¹À»¼ö·Ï ±³Á¤Ä¡·á ºÒÆíÇÏ´Ù... ÀÌÁ¦´Â ´õ ÀÌ»ó »ç½ÇÀÌ ¾Æ´Õ´Ï´Ù. ¹Ì´ÏÆ©ºê´Â profile ÀÌ ÀÛ¾Æ ¿¬Á¶Á÷ ÀÚ±ØÀÌ ÀüÇô ¾ø°í, light force¸¦ »ç¿ëÇϹǷΠ±³Á¤·Â Àû¿ë¿¡ µû¸¥ µ¿Åë ¶ÇÇÑ ÀüÇô ¾ø½À´Ï´Ù. MTA·Î Ä¡·á¹Þ´Â ¸ðµç ÁßÀå³âµéÀÌ ³Ê³ª ÇÒ°Í ¾øÀÌ À̾߱âÇÕ´Ï´Ù. ±³Á¤Ä¡·á, ÀÌ·¸°Ô Æí¾ÈÇÒ ¼ö°¡! ÀÌ·²ÁÙ ¾Ë¾ÒÀ¸¸é ÁøÀÛ Ä¡·áÇÒ °ÍÀ»!



Á¦2¼º  Å©¶ó¿ìµùÀÌ ¾Æ¹«¸® ½ÉÇصµ ¿ÍÀ̾î Àû¿ë °¡´É !

Å©¶ó¿ìµùÀÌ ½ÉÇÑ °æ¿ì¿¡´Â Æ©ºê¸¦ ºÎÂøÇÑ ÈÄ ¿ÍÀ̾ ³Ö´Â °ÍÀÌ ¸Å¿ì ¹ø°Å·Ó°Å³ª ¶§·Î´Â ºÒ°¡ÇÒ ¼öµµ ÀÖ½À´Ï´Ù. ±×·¯³ª »õ·ÎÀÌ °í¾ÈµÈ Forced positioning Å×Å©´ÐÀ» ÅëÇØ ¡°¿ÍÀ̾î¿Í ÇÔ²²¡± Æ©ºê¸¦ ¿øÇÏ´Â À§Ä¡¿¡ ÀÚÀ¯ÀÚÀç·Î ºÎÂøÇÒ ¼ö ÀÖ½À´Ï´Ù. Ä¡·á óÀ½ºÎÅÍ ¸ðµç Ä¡¾Æ¿¡ ±³Á¤·Â Àû¿ëÀÌ °¡´ÉÇϹǷΠ°¡´ÉÇÕ´Ï´Ù. ÁßÀå³â¿¡¼­µµ ºü¸¥ ±³Á¤ÀÌ !

Á¦3¼º  Precision alignment, ¹Ì´ÏÆ©ºê¸¸ÀÌ °¡´É!

¹Ì¼¼ÇÑ È¸Àüµµ °¨¼öÇÒ ¼ö ¾ø´Ù Çϴ ȯÀÚ°¡ ÀÖ´Ù¸é MTA ¸¸ÀÌ À¯ÀÏÇÑ ±³Á¤ÀåÄ¡. One-side flattened tube ¸¦ »ç¿ëÇÒ °æ¿ì ¡°¿Ïº®ÇÏ°Ô¡± °¡Áö·±ÇÑ Ä¡¿­À» ÀÚµ¿ÀûÀ¸·Î ¾òÀ» ¼ö ÀÖ½À´Ï´Ù. ƯÈ÷ Ä¡Á¶°ñ ÁöÁö°¡ ¾È ÁÁÀº °æ¿ì ¹Ì¼¼Á¶ÀýÀº ¹Ì´ÏÆ©ºê ¸¸ÀÌ °¡´ÉÇÕ´Ï´Ù. profile Àº ÀÛÀ¸³ª ±æÀÌ´Â 3mm·Î ȸÀü ¹× °¢µµ Á¶Àý¿¡¼­µµ ¸Å¿ì Ź¿ù !

Á¦4¼º  012 NiTi ·Î ¾Ç±ÃÇüűîÁö ±³Á¤ °¡´É !

¹ÏÀ» ¼ö ÀÖ³ª¿ä? 012 NiTi ±× ¾àÇÑ ¿ÍÀ̾î Çϳª·Î ¾Ç±ÃÇüÅ °³¼±±îÁö °¡´ÉÇÏ´Ù´Â °ÍÀ». ÈÄ¹æ ¼Ò±¸Ä¡ Æ©ºêÀÇ ±Ù½É ¹× ¿ø½É Æ÷Áö¼Å´×À¸·Î Àü¹æ °ßÄ¡ÀÇ ¼³Ãø ¶Ç´Â ÇùÃø À̵¿ÀÌ °¡´ÉÇÑ ¹Ù ºñ´ëĪġ¿­, ¾çÃø ¹× ÆíÃø ¹Ý´ë±³ÇÕ µî complicated case ±îÁö ¸ðµÎ Æí¾ÈÇÏ°Ô ¸Å´ÏÁö °¡´É ÇÕ´Ï´Ù !

Á¦5¼º  ¹ßÄ¡°ø°£ Ŭ·ÎÁ®, tipping ¾øÀÌ °¡´ÉÇÑ°¡ !

ÇÏÀüÄ¡ ÀÏÄ¡ ¹ßÄ¡ µî ÁßÀå³â¿¡¼­ÀÇ ¹ßÄ¡°ø°£ Ŭ·ÎÁ®, tipping¾øÀÌ MTA·Î °¡´ÉÇÕ´Ï´Ù. Non-invasive TAD ÀÎ Passive wire bondingÀ¸·Î ¾ÞÄ¿¸¦ º¸°­ÇÏ°í super-light ÈûÀ» ³»´Â Ưº°ÇÑ Ã¼Àΰú ÇÔ²² direct-bonded E-thread Tie µîÀÇ Å×Å©´ÐÀ» »ç¿ëÇÒ °æ¿ì Ä¡ÁÖÁöÁö°¡ ºÒ·®ÇÑ »óÅ¿¡¼­µµ tipping ¾øÀÌ °ø°£ Ŭ·ÎÁ®°¡ °¡´ÉÇÕ´Ï´Ù !


Á¦6¼º  Ä¡ÁÖ°¡ ¾Æ¹«¸® ¾È ÁÁ¾Æµµ ±³Á¤Ä¡·á °¡´É !

ÁÖÀ§ Ä¡Á¶°ñ ÁöÁö°¡ ³·¾ÆÁø °æ¿ì ´Ü¼øÈ÷ light force¸¸À¸·Î´Â ÃæºÐÄ¡ ¾Ê½À´Ï´Ù. "light intermittent" °³³äÀÇ ÈûÀû¿ëÀÌ ÇÊ¿äÇÕ´Ï´Ù. À̸¦ À§ÇØ Æ¯º°È÷ °³¹ßµÈ 45¡ÆC thermo-active NiTi¸¦ ¼Ò°³ÇÕ´Ï´Ù. ÀÌÁ¦´Â °¡´ÉÇÕ´Ï´Ù. Ä¡ÁÖÁúȯÀ¸·Î ÀÎÇØ pathologic tooth migration ÀÌ ¾Æ¹«¸® ½ÉÇÏ°Ô ³ªÅ¸³ªµµ !





°­ÀÇ ³»¿ë

. Rationale and Development of MTA
. Instrument and Materials for MTA practice
. Bonding / Indirect bonding of MTA
. Stripping, when and how
. Management of Spool type NiTi wire
. Wire engagement for MTA practice
. Indirect bonding ¡°withWire¡± technique
. 40¡ÆC and 45¡ÆC Thermo-active NiTi
. Resin tube and/or "Silver" tube
. A new appliance for comprehensive cases, 022 tube
. Forced positioning technique in severe crowding case!
. Precision alignment is possible only with MTA!
. Correction of skewed arch form using light NiTi
. A should-have concept for middle-aged adults, pain-free orthodontics
. Non-invasive TAD, Passive wire bonding!
. MTA clinical workflow
. Practice build-up with MTA
. Clinical Case Presentation



µî ·Ï ¾È ³»
                  »çÀüµî·Ï             ÇöÀåµî·Ï
                 3¿ù1ÀÏ(¸ñ)±îÁö     
 ÀϹÝÄ¡°úÀÇ          10¸¸¿ø           15¸¸¿ø           
Àü°øÀÇ,±ºÁø,°øº¸ÀÇ      4¸¸¿ø            8¸¸¿ø          

* »çÀüµî·ÏÀÚ¿¡ ÇÑÇÏ¿© certificate µå¸³´Ï´Ù.
* µî·Ï½Ã ¸ÞÀÏ ÁÖ¼Ò·Î °­¿¬ÈÄ ÀÓ»óÀÚ·á Á¦°øÇØ µå¸³´Ï´Ù.
* ȯÀÚ ÃÊ»ó±Ç º¸È£¸¦ À§ÇÏ¿© ºñµð¿À ÃÔ¿µÀº ÇÏÁö ¾Ê½À´Ï´Ù.

¿Â¶óÀÎ ÀÔ±Ý  ÇϳªÀºÇà 928-910001-58004 Á¤Á¤¾Æ  
            
¿Â¶óÀÎ ÀԱݽà Âü°¡ÀÚ ¼ºÇÔÀ» ¸í±âÇÏ¿© ÁÖ½Ã°í ¸ÞÀÏÀ̳ª Æѽº·Î µî·Ï»çÇ×(¼ºÇÔ, ¿µ¹®¼ºÇÔ, ¸éÇã¹øÈ£, ±Ù¹«Ã³, ¿¬¶ôÀüÈ­¹øÈ£)À»  ¾Ë·Á Áֽñ⠹ٶø´Ï´Ù.

½Åû   ÀüÈ­: (02) 442-3735 À¯Á¤À± ½ÇÀå    FAX: (02) 489-2805
E-mail: emaster@adultortho.org  Web site: www.adultortho.org



                 ÇÑ ±¹ ¼º ÀÎ Ä¡ °ú ±³ Á¤ ¿¬ ±¸ ȸ

--------------------------------------------------------------

Ä¡Àǽź¸ ±¤°í¸¦ º¸½Ã·Á¸é ¿©±â¸¦ ´­·¯ÁÖ¼¼¿ä




Backward Forward Post Reply List